Ventilation is a requirement of the Canadian Building Code of Canada
(section 9.19.)
Ventilation is a criteria required by
shingle manufacturers in order to
respect their warranty.
The two fundamental benefits of an effective attic ventilation system are:
|
|
A cooler attic in summer |
|
|
A dryer attic in winter |
Both benefits result in energy savings, greater homeowner comfort,
and
higher integrity of the dwelling.
Summer:
Summer heat, trapped in the attic, creates a furnace effect, heating
ceiling insulation, which then conducts heat through to the ceiling,
and this heat is then radiated downward to persons and objects in
the rooms below. This is why it is much warmer upstairs in the
bedrooms than downstairs in the basement!
Other problems that arise by this are the curling, or the bleeding of shingles, and the warping of the sheathing. The air conditioner is working continuously to cool down the living area.
Winter:
Winter conditions bring a different type of problem. During the
cold months of the year, the air inside the home is warmer and
carries more water vapour than the colder, dryer air in the attic.
Cooking, laundry, showers, humidifiers and other activities
using water contribute to this condition. There is a strong natural
force, termed “vapour pressure”, that causes water vapour to
migrate from high-humidity air or materials to low-humidity air.
This migration of water vapour passes through ceilings, insulation
and wood and even successfully circumvents a vapour barrier. It
moves into the attic space where it can readily condense into liquid
water on the cooler structural members-rafters, trusses, and
especially the cold roof sheathing.
Condensation moisture within an attic or ceiling space can dampen
and compress insulation. Even small amounts of condensation can
have a substantial effect in reducing the "R" value of the insulation,
thus
creating faster heat loss into the attic space. This will eventually
lead
to mould, mildew, rot, ice damming, etc…
Solution: A Cold Roof
Though a number of factors enter into the formation of condensation and ice dams, the fundamental problem is undesirable attic heat, which results in a warm roof space. The solution is to maintain a cold roof. It is essential that the air in the attic be the same or as close to temperature of the air outside.
Most common contribution to moisture within an attic space:
The most common practices in the building industry which is a major
contribution to moisture problems
is the discharging of washroom fans, hood ranges, dryer vents and
air exchangers, down through the
soffits. This practice defeats the purpose of moisture control
within a building envelope. The soffits are
the air intake for attic ventilation, so when exhaust fans are
discharging down into the soffit areas, most
all of this warm and humid air comes right back into the attic
space, thus contributing to ice damming
and moisture problems, which can eventually lead to mould & mildew
and rot, not to mention the loss
of r-value of your insulation. Try and image a washroom fan with an
evacuation of 60 cfm. This is 60
cubic feet of warm and humid air per minute that goes right back
into your attic space. Now image if
you have two or more with a higher cfm! All exhaust fans which
protrude through the ceiling into the
attic space should exhaust out through the roof by using a roof
exhaust vent especially designed and
built for this kind of situation. Access doors leading into the
attic space should be properly insulated to
the same r-value or more to what the attic itself is. All heating
ducts, potlights, exhaust fans, and
plumbing vent stacks should all be verified and properly insulated
to reduce unnecessary heat loss into
the attic space. The insulation should never obstruct air flow from
the soffit air intake area at the eaves,
this will prevent attic air circulation.
Which Ventilation System to choose – Static Ventilator or Passive
Ventilator:
Few people recognize the difference between a passive ventilator and
a static ventilator. A static
ventilator allows air exchange, where as a passive ventilator allows
for evaporation. Passive ventilators
would be low profile vents like ridge vents, mushroom vents, or even
a gooseneck ventilator for flat
roofs. They do not allow for air exchange but merely let the air
evaporate out through them. The air
enters through the soffits into the attic, then gradually escaping
out through the ventilator.
The drawbacks:
A passive vent releases the attic air but is unable to exchange or
replace it frequently. Being so low, it
is usually buried by snow after the first snowstorm, rendering the
ventilation system obsolete, and that,
just when you need it the most. No protection against water or snow
infiltration, especially in windy
conditions.
A Static Ventilator would be turbine ventilators and Maximum Ventilators. They can both replace the attic air, and they both function with the combination of wind and pressure differential, creating a chimney effect, replacing the attic air.
The Difference
The Maximum Ventilator model 301 has a greater drawing power than the turbine because of its design.
With only a four-mi./hr wind, the Maximum Ventilator is replacing the attic air of an average size home of 1200 sq. ft, at a rate of 418 cfm., thus an average of every twenty minutes! (It would take two 14 inches or three 12 inches turbines to replace one model 301).
The turbine ventilator must turn in order to prevent water or snow infiltrations, as for the Maximum ventilator has a storm proof deflector system preventing infiltrations, even in high gust of winds. The Maximum ventilators have no moving parts, are silent, and maintenance free. Due to its height, it can withstand an abundance of snow without being covered, making it an efficient ventilator year round. Built and tested to withstand winds of up to 175 km/h (110 mph). Maximum Ventilators come in all type of models to suit each building need, whether it is sloped or flat roofs. Maximum Ventilators also has built-in wire mesh grill protecting the home from unwanted birds and rodents. Finally, the Maximum Ventilators come in three different colours so that they may blend in with the shingles, and have a lifetime limited guarantee on all manufacturing defects.
Which Ventilator to Choose
Important Factors to Consider:
|
|
|
** Soffits must be well-ventilated; air circulation in soffits must be unobstructed by insulation. |
|
|
** Attic insulation should have a minimum rating of R-30. |
|
|
** Access door to the attic should be well-insulated. |
|
|
** Air evacuation ducts should not discharge into the attic. |
|
|
** Any openings other than Maximum Ventilators or the soffits must be completely sealed. |
|
|
** Choose the Maximum Ventilator best-suited for your home according to the manufacturer’s recommendations. (See chart above) |
|
|
** The specifications, mentioned above, do not apply for cathedral roofs. |